Item #1051728 Model #GOLD DB25XLRF20

Mogami Gold 8 Channel DB25-XLR Female Snake Cable 20 ft.

$329.95

Availability
Delivery
Out of stock
Pickup In-Store

This item is backordered but it is available to reserve now. You will not be charged until the item ships.

Email me when in stock

Save to Wishlist

Incredible Cable.

Mogami Gold multicore cables are designed for the highest level of audio performance and feature superb electrical and mechanical characteristics while remaining compact, superflexible and easy to use.
Specifications
  • Conductor: 30/0.08A (0.15mm sqœ) #26AWG (30…#40AWG)
  • Insulation: 1.0 XLPE (Cross Linked Polyethylene) (0.039")
  • Drain Wire: 7/0.18TA (0.18mm sqœ) #25AWG (7…#33AWG)
  • Served Shield: Approx. 58/0.10A Served (spiral) Shield
  • Jacket (Covering): 2.8 Flexible PVC (0.110")
  • Identification: See core number identification table
  • DC Resistance at 20 deg C: Inner Pair Conductor: 0.13W/m(0.040W/Ft); Shield: 0.031W/m(0.0095W/Ft)
  • Capacitance at 1kHz, 20 deg C (Partial Capacitance Value) See Figure (1): K0: 130pF/m(40pF/Ft); K1: 12pF/m(3.7pF/Ft)
  • Inductance: 0.6H/m(0.18H/Ft)
  • Electrostatic Noise (Hum Pick-up)*: 2.5mV Max.
  • Electromagnetic Noise at 10kHz*: (Inductance of the toroidal core: 595H): 0.1mV Max.
  • Microphonics*: Method: Stepping on cable: 50mV Max. at 50kW Load
  • Voltage Breakdown: Must withstand at DC 500V/15sec.
  • Insulation Resistance at DC 125V, 20 deg C: 100000 MW … m Minimum
  • Tensile Strength of one pair (26 deg C, 65% RH): 274N
  • Emigration: Non-emigrant to ABS resin
  • Applicable Temperature: -20 deg C +70 deg C(-4 deg F +158 deg F)
  • Standard: UL13 CL2X 60 deg C / UL 20002 AWM 30V 60 deg C VW-1
  • Conductor: 7/0.18A (0.178mmœ) #25AWG (7…#33AWG)
  • Insulation: 1.05 XLPE (Cross Linked Polyethylene) (0.0413")
  • Drain Wire: 7/0.18A (Exactly same as conductor)
  • Shield: Approx. 58/0.10A Served (spiral) Shield
  • Jacket (Covering): 2.8 Flexible PVC (0.110")
  • Identification: See core number identification table
  • DC Resistance at 20 deg C: Inner Pair Conductor: 0.11W/m(0.0336W/Ft)
  • Shield: 0.031W/m(0.0095W/Ft)
  • Capacitance at 1kHz, 20 deg C (Partial Capacitance Value) See Figure (2): K0: 140pF/m(42.7pF/Ft)
  • K1: 12pF/m(3.7pF/Ft)
  • Inductance: 0.6H/m(0.18H/Ft)
  • Electrostatic Noise (Hum Pick-up)*: 2.5mV Max.
  • Electromagnetic Noise at 10kHz*
  • (Inductance of the toroidal core: 595H): 0.1mV Max.
  • Microphonics* Method: Stepping on cable: 50mV Max. at 50kW Load
  • Voltage Breakdown: Must withstand at DC 500V/15sec.
  • Insulation Resistance at DC 125V, 20 deg C: 100000 MW … m Minimum
  • Tensile Strength of one pair (26 deg C, 65% RH): 274N
  • Emigration: Non-emigrant to ABS resin
  • Applicable Temperature: -20 deg C +70 deg C(-4 deg F +158 deg F)
  • Standard: UL13 CL2 60 deg C

Features

  • Individually twisted shielded pairs.
  • XLPE (Cross Linked Polyethylene) insulation provides superb electrical characteristics and will not melt or shrink back during soldering.
  • Rugged and flexible construction that is easy to handle, even at temperatures down to -20 deg C (-4 deg F).
  • Easy cable identification system:
  • Channel numbers are printed and underlined on each core jacket to ensure correct identification, regardless of which end is stripped.
  • Outer jackets of each pair are color coded by standard resistor color code, allowing quick identification of conductor pairs.
  • Inner conductors are also color coded based on the international standard resistor color code. Each pair is color coded by jacket and conductor color combination.
  • Each channel has a drain wire and served (spiral) bare copper shield. The drain wires simplify termination and can be crimped by the same size contact as the inner conductor pair.
  • CL2 rated version available. Conductor size of CL2 rated version is thicker #25AWG so that it is also recommended for rugged application and firm and easier crimp terminal connector wiring as well as NEC fire regulation requirement.
warning

WARNING: This product can expose you to chemicals including Carbon black (airborne, unbound particles of respirable size), which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.